Search results for "instrumentation [Diffusion Magnetic Resonance Imaging]"
showing 10 items of 2402 documents
Study of supersymmetric signals with R-parity violation in ATLAS at LHC
2013
219 páginas. Tesis Doctoral del Departamento de Física Atómica, Molecular y Nuclear, de la Universidad de Valencia.
Real-time data processing in the ALICE High Level Trigger at the LHC
2019
At the Large Hadron Collider at CERN in Geneva, Switzerland, atomic nuclei are collided at ultra-relativistic energies. Many final-state particles are produced in each collision and their properties are measured by the ALICE detector. The detector signals induced by the produced particles are digitized leading to data rates that are in excess of 48 GB/$s$. The ALICE High Level Trigger (HLT) system pioneered the use of FPGA- and GPU-based algorithms to reconstruct charged-particle trajectories and reduce the data size in real time. The results of the reconstruction of the collision events, available online, are used for high level data quality and detector-performance monitoring and real-tim…
Observatory science with eXTP
2019
Disponible preprint en: arXiv:1812.04023v1 [astro-ph.HE] [v1] Mon, 10 Dec 2018 19:00:52 UTC (4,376 KB)
Measurement of three-dimensional mirror parameters by polarization imaging applied to catadioptric camera calibration
2008
International audience; We present a new efficient method for calibration of cata- dioptric sensors. The method is based on an accurate measurement of the three-dimensional parameters of the mirror through polariza- tion imaging. While inserting a rotating polarizer between the cam- era and the mirror, the system is automatically calibrated without any calibration patterns. Moreover, this method permits most of the constraints related to the calibration of catadioptric systems to be relaxed. We show that, contrary to our system, the traditional meth- ods of calibration are very sensitive to misalignment of the camera axis and the symmetry axis of the mirror. From the measurement of three-di…
A comparative study of the behaviour of silver, copper and nickel submitted to a constant high power flux density
2005
In this paper, we present a numerical simulation of three metal cathode (silver, copper and nickel) submitted to a constant flux power flux density ranging between and . The goal is to compare the interface evolution (vaporization and liquefaction rate, appearance time of liquid and vapour, energetic repartition) to predict the behaviour of the cathodes during an electric arc.
Relaxation of electron-hole pairs and scintillation mechanism in alkali halide crystals
1997
Abstract The mechanism of the ionizing radiation energy transfer from host lattice to luminescence centers is discussed taking into account the results of the recent experimental investigations of electron-hole pair relaxation in alkali iodide crystals. The high scintillation yield in CsI-Tl, CsI-Na and partially in Nal-Tl crystals is explained by the process of the motion and capture of a one-center self-trapped exciton by impurity ions.
1981
A new interferometer has been designed in order to perform measurements of refractive indices and refractive index increments on liquid systems under elevated pressure at different temperatures. The method of measurement, the calibration of the instrument and the treatment of data are described. With a series of test measurements on trans-decalin it is shown that with this instrument reliable results are obtained.
The detection efficiency of the clover Ge-detectors array at the RITU-GREAT facility
2015
Absolute detection efficiency depending upon its position along the beam line is determined for three germanium detectors, that are part of the GREAT spectrometer at the RITU separator focal plane. The efficiency is determined for an energy range from 80 keV to 1400 keV for all three detectors as an array and also individually using digital electronics. The optimal position for the detector array has been defined for two configurations of the GREAT spectrometer: with planar detector and without it. The obtained results have been compared with three references: a simulation prepared especially for this setup by another student, a previous study that was carried out by applying analogue elect…
Thermoelectric Radiation Detector Based on Superconductor-Ferromagnet Systems
2017
We suggest an ultrasensitive detector of electromagnetic fields exploiting the giant thermoelectric effect recently found in superconductor-ferromagnet hybrid structures. Compared with other types of superconducting detectors where the detected signal is based on variations of the detector impedance, the thermoelectric detector has the advantage of requiring no external driving fields. This is especially relevant in multipixel detectors, where the number of bias lines and the heating induced by them are an issue. We propose different material combinations to implement the detector and provide a detailed analysis of its sensitivity and speed. In particular, we perform a proper noise analysis…
Status of Advanced Virgo
2017
The LIGO and the Virgo collaborations have recently announced the first detections of Gravitational Waves. Due to their weak amplitude, Gravitational Waves are expected to produce a very small effect on free-falling masses, which undergo a displacement of the order of 10-18 m for a Km-scale mutual distance. This discovery showed that interferometric detectors are suitable to reveal such a feeble effect, and therefore represent a new tool for astronomy, astrophysics and cosmology in the understanding of the Universe. To better reconstruct the position of the Gravitational Wave source and increase the signal-to-noise ratio of the events by means of multiple coincidence, a network of detectors…